STMicroelectronics BTB40-600B
40A TRIACS
FEATURES
: Symbol IT(RMS) V DRM/VRRM IGT (Q1) Value 40 600 and 800 50 Unit A V mA G G A2 A1 A1 A2DESCRIPTION
Available in high power packages, the BTA/ BTB40-41 series is suitable for general purpose AC power switching. They can be used as an ON/ OFF function in applications such as static relays, heating regulation, water heaters, induction motor starting circuits, welding equipment... or for phase control operation in high power motor speed controllers, soft start circuits... Thanks to their clip assembly technique, they provide a superior performance in surge current handling capabilities. By using an internal ceramic pad, the BTA series provides voltage insulated tab (rated at 2500 V RMS) complying with UL standards (File ref.: E81734).ABSOLUTE MAXIMUM RATINGS
Symbol IT(RMS) RMS on-state current (full sine wave) Parameter RD91 (BTA40) A2 A1 A2 G A1 A2 G TOP3 Insulated (BTA41) TOP3 (BTB41) Value RD91 TOP3 TOP3 Ins. F = 60 Hz F = 50 Hz tp = 10 ms F = 120 Hz tp = 10 ms tp = 20 µs Tj...