DESCRIPTION
A RESET output is generatedat REG4’s decay. External protection must be provided for reverse battery protection. REG1 10V, 40mA 10V-REG1 REG2 8.5V, 175mA 8.5V-REG2 CURRENT LIMIT REG3 5V, 650mA 5V-REG3 RESET LVWarn RESET LVW REG4 5V, 100mA 5V-REG4-STBY EN1 OUTPUT CONTROL THERMAL SHUTDOWN OVERVOLTAGE PROTECTION HSD1 2.0A HSD2 0.3A HSD3 0.3A HSD1 EN2 HSD2 EN3 GND HSD3 D95AU346 June 2000 1/7 L4954 ABSOLUTE MAXIMUM RATINGS
Symbol VS VS VS,ovs Vin V out Top Tstg Parameter DC Operating Supply Voltage Transient Supply Overvoltages, rise time = 10ms delay time = 115ms Overvoltage Shutdown Input Voltages (EN1, EN2, EN3) Output Voltages (LVWarn, RESET) Operating Temperature Range Storage Temperature Range Value -0.6 to 26.5 34 27 -0.6 to 6.0 -0.6 to 6.0 -40 to 85 -40 to 150 Unit V V V V V °C °C PIN CONNECTION 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 10V REG1 8.5V REG2 5V REG3 EN3 EN2 EN1 RESET GND LVWarn 5V REG4-STBY ST CAP HSD3-0.3A HSD2-0.3A VS HSD1-2A TAB CONNECTED TO PIN 8 D95AU347 THE...