Description
The SMC50J TVS series are designed to protect sensitive equipment against electrostatic discharges according to IEC 61000-4-2, MIL STD 883 Method 3015, and electrical overstress such as IEC 61000-4-4 and 5.
They are used for surges below 5000 W 10/1000 μs.
Features
- Peak pulse power:.
- 5000 W (10/1000 μs).
- up to 48 kW (8/20 μs).
- Stand-off voltage range from 5 V to 100 V.
- Unidirectional type.
- Low leakage current: 0.2 µA at 25 °C.
- Operating Tj max: 175 °C.
- JEDEC registered package outline.
- Resin meets UL94, V0.
- Lead finishing: matte tin plating
Complies with the following standards.
- UL94, V0.
- J-STD-020 MSL level 1.
- J-STD-002, JESD 22-B102 E3 an.