DESCRIPTION
When used as high and low side in buck regulators, it gives the best performance in terms of both conduction and switching losses. This is extremely important for motherboards where fast switching and high efficiency are of paramount importance. INTERNAL SCHEMATIC DIAGRAM APPLICATIONS
s SPECIFICALLY DESIGNED AND OPTIMISED FOR HIGH EFFICIENCY DC/DC CONVERTERS ABSOLUTE MAXIMUM RATINGS
Symbol VDS VDGR VGS ID ID IDM(●) Ptot EAS (1) Tstg Tj February 2002 . Parameter Drain-source Voltage (VGS = 0) Drain-gate Voltage (RGS = 20 kΩ) Gate- source Voltage Drain Current (continuos) at TC = 25°C Drain Current (continuos) at TC = 100°C Drain Current (pulsed) Total Dissipation at TC = 25°C Derating Factor Single Pulse Avalanche Energy Storage Temperature Max. Operating Junction Temperature Value 30 30 ± 16 35 25 140 50 0.33 300 -55 to 175 (1) Starting T j = 25 oC, ID = 17.5 A, VDD= 24 V Unit V V V A A A W W/°C mJ °C (●) Pulse width limited by safe operating area. 1/10 STD35NF3LL/STD35NF3L...