Datasheet4U.com

STM1061 Datasheet PDF

STMicroelectronics STM1061

The STM1061 low power voltage detector provides monitoring of battery, power-supply, and regulated system voltages. When VCC falls below a specified trip point threshold, the output (OUT) is forced low and remains asserted as long as the VCC input remains below VTH– + hysteresis (VHYST). The STM1061 device is guaranteed to output the correct logic state for VCC down to 0.7V.
Part No. STM1061
Datasheet STM1061 Download
Manufacturer
STMicroelectronics
Description Low Power Voltage Detector
Buy Stock & Price
STM1061 datasheet page 1 preview

FEATURES

● Factory-trimmed Voltage Thresholds in 0.1V Increments from 1.6 to 5.5V
● ±2% Voltage Threshold Accuracy
● Operating Voltage 0.7 to 6.0V
● Open Drain Output
● Low Supply Current of 0.9µA (typ)
● Guaranteed OUT Assertion Down to VCC = 0.7V
● Power Supply Transient Immunity
● Available in SOT23-3 and SOT323-3 (SC70-3) packages
● Operating Temperature –40 to 85°C. Figure 1. Packages SOT23-3 (WX) SOT323-3, SC70-3 (W) (1) 1. Contact local sales office for availability. July 2006 Rev 4 1/23 1 STM1061 1 Summary

DESCRIPTION

Summary

DESCRIPTION

A precision voltage reference and comparator monitors the VCC input and compares it with a specified voltage threshold condition. They are also designed to ignore fast transients on VCC. This small, low power device is ideal for portable applications and is available in spacesaving SOT23-3 and SOT323-3 (SC70-3) packages. Figure 2. Logic Diagram VCC STM1061 OUT VSS AI10477 Table 1. Signal Names OUT Open Drain Active-Low Output VCC Supply Voltage VSS Ground Figure 3.
STM1061 page 2 preview STM1061 page 3 preview