THBTxxx11D
TRIPOLAR OVERVOLTAGE PROTECTION FOR TELECOM LINE
Application Specific Discretes A.S.D.™
FEATURES BIDIRECTIONAL CROWBAR PROTECTION BETWEEN TIP AND GND, RING AND GND AND BETWEEN TIP AND RING. PEAK PULSE CURRENT : IPP = 30A for 10/1000µs surge. HOLDING CURRENT : IH = 150mA. AVAILABLEIN SO8 PACKAGES. LOW DYNAMIC BREAKOVER VOLTAGE. DESCRIPTION Dedicated to telecommunication equipment protection, these devices provide a triple bidirectional protection function. They ensure the same protection capability with the same breakdown voltage both in longitudinal mode and transversal mode. A particular attention has been given to the internal wire bonding.