Sanken RU4C
Silicon Diode
APPLICATIONS
Pulse Rectification, etc. Not Recommended for New Designs 3 Absolute maximum ratings No. Item 1 Transient Peak Reverse Voltage 2 Peak Reverse Voltage Symbol Unit VRSM VRM V V 3 Average Forward Current IF (AV) A 4 Peak Surge Forward Current 5 Junction Temperature 6 Storage Temperature IFSM Tj Tstg A ℃ ℃ Rating 1050 1000 1.5 (Ta=40℃) 2.5 (Ta=60℃) 50 -40~ +150 -40~ +150 Conditions With out Fin With Fin Refer to 6 10msec. Half sinewave, one shot 4 Electrical characteristics (Ta=25℃, unless otherwise specified) No. Item Symbol Unit 1 Forward Voltage Drop 2 Reverse Leakage Current 3 Reverse Leakage Current Under High Temperature 4 Reverse Recovery Time VF V IR µA H・IR µA Trr-1 Trr-2 µs µs 5 Thermal Resistance Rth(j-l) ℃/W Value 1.60 max. 50 max. 500 max. 0.4 max. 0.18 max. 8 max. Conditions IF=3.0A VR=VRM VR=VRM, Tj=100℃ IF=IRP=0.1A, Ta=25℃ 90% Recovery point IF=0.1A, IRP=0.2A, Ta=25℃ 75% Recovery point Between Junction and Lead 040907 1/3 61426-01 SANKEN ELECTRIC CO., LTD. 5 VF test and test circuit RU4C PercentageNot Reco tomratedmforwardencurrentded(%)for New Designs 6 Derating Derating to the ambient temperature.