ABSOLUTE MAXIMUM RATINGS
at Ta = 25°C, VSS = 0 V Parameter Maximum supply voltage Symbol VDD max VIN1 max Maximum input voltage VIN2 max VIN3 max VO1 max Maximum output voltage VO2 max VO3 max IO1 max Maximum output current IO2 max IO3 max Allowable power dissipation Operating temperature Storage temperature Pd max Topr Tstg VDD CE, DI, CL, AINa, AINb XIN, FMINa, FMINb, AMIN, IFIN1, IFIN2/I1 IO2 DO XOUT, PDa, PDb BO1 to BO4, IO2, AOUTa, AOUTb BO1 DO, AOUTa, AOUTb BO2 to BO4, IO2 Ta ≤ 85°C Conditions Ratings –0.3 to +7.0 –0.3 to +7.0 –0.3 to VDD +0.3 –0.3 to +15 –0.3 to +7.0 –0.3 to VDD +0.3 –0.3 to +15 0 to +3.0 0 to +6.0 0 to +10.0 200 –40 to +85 –55 to +125 Unit V V V V V V V mA mA mA mW °C °C Allowable Operating Ranges at Ta = –40 to 85°C, VSS = 0 V Parameter Supply voltage Symbol VDD VIH1 Input high-level voltage VIH2 VIH3 Input low-level voltage Output voltage VIL VO1 VO2 fIN1 fIN2 Input frequency fIN3 fIN4 fIN5 VIN1 VIN2-1 VIN2-2 Input amplitude VIN3 VIN4 VIN5 VIN6 Guaranteed cry...