ABSOLUTE MAXIMUM RATINGS
at Ta = 25°C, VSS = 0 V Parameter Maximum supply voltage Input voltage Output voltage Symbol VDD max VIN VOUT (1) VOUT (2) IOUT (1) IOUT (2) Output current IOUT (3) IOUT (4) IOUT (5) Allowable power dissipation Operating temperature Storage temperature Note: * Reference value Pd max Topr Tstg All input pins Port PJ All output ports other than VOUT (1) Port PJ PE, PF, PG, PK, PM, PN, EO1, EO2 Ports PB and PC S1 to S32 COM1 to COM3 Ta = –45 to 85°C Conditions Ratings –0.3 to +6.5 –0.3 to VDD + 0.3 –0.3 to +15 –0.3 to VDD + 0.3 0 to +5 0 to +3 0 to +1 300 3 300 –40 to +85 –45 to +125 Unit V V V V mA mA mA µA mA mW* °C °C Allowable Operating Ranges at Ta = –40 to +85°C, VDD = 3.5 to 5.5 V Parameter Symbol VDD (1) Supply voltage VDD (2) VDD (3) VIH (1) Input high-level voltage VIH (2) VIH (3) VIH (4) VIL (1) Input low-level voltage VIL (2) VIL (3) VIL (4) fIN (1) fIN (2) fIN (3) fIN (4) Input frequency fIN (5) fIN (6) fIN (7) fIN (8) VIN (1) Input amplitude VIN (2)...