DESCRIPTION
Using the MILSTD-883 (Method 3015) specification of Human Body Model (HBM), the device provides protection to greater than ±20kV. M BD SOT-143 C H A N J K G L E Millimeter Min. Max. 2.80 3.00 2.25 2.55 0.90 1.10 1.20 1.40 1.60 2.00 0.57 REF. 0.40 REF. F Millimeter Min. Max. 0.75 0.90 0.08 0.16 0.10 1.90 REF. 0.30 0.50 APPLICATIONS
Digital Cameras Portable Instrumentation Notebooks, Desktops, and Serves Personal Digital Assistants (PDAs) Cell phone handsets and accessories REF. A B C D E F G REF. H J K L M N FEATURES
low clamping voltage Low leakage current Small package MARKING 6V8 = Date Code PACKAGE INFORMATION Package SOT-143 MPQ 3K Leader Size 7 inch ABSOLUTE MAXIMUM RATINGS
(TA=25°C unless otherwise specified) Rating Air contact IEC 61000-4-2 (ESD) Contact discharge Peak pulse power (tp=8/20us) Peak pulse current (tp=8/20us) Storage temperature range Lead temperature . Symbol Value ±15 Unit kV ±8 PPK IPP TJ, TSTG TL 450 20 150, -55 ~ 150 260 W A ° C ° C Any changes of specification will not be informed individually.