Q-62702-G66
CGY 121 A
Ga As MMIC Preliminary Datasheet l l l l l l l
RF-in; -Vg Vcontrol 6 RF-GND 5 4
Variable gain amplifier (MMIC-Amplifier) for mobile munication Typical Gain Control range over 50d B Positive Control Voltage 50Ω input and output matched Low power consumption Operating voltage range: 2.7 to 6 V Frequency range 800 MHz ... 2.5 GHz
3 2 1 Vd2; RF-out RF-GND Vd1
ESD: Electrostatic discharge sensitive device, observe handling precautions!
Type
Marking
Ordering code (taped)
Package
1)
CGY 121 A
Y9S
MW-6
Maximum ratings Characteristics Drain voltage Neg. supply voltage Pos. control voltage Channel temperature Storage temperature range Total power dissipation (TS < 81°C) 2) Thermal resistance Characteristics Channel-soldering point (GND)
1) 2)
Symbol max. Value 8 -8 4 150 -55...+150 550
Unit V V V °C °C m W
VD VG Vcon TCh Tstg Ptot
Symbol max. Value 125
Unit K/W
Rth Ch S
Dimensions see page 9. Please care for sufficient heat dissipation on the pcb!
- )...