VF4 series
40 Amp Relay With PC Board or Quick Connect Terminals for Automotive Applications
Features
• • • • • 40A continuous contact rating @ 85°C. 1 Form A and 1 Form C arrangements. Plug-in or PC board terminals. Optional mounting bracket. Various enclosure options.
Operate Data
Must Operate and Must Release Voltage: See Coil Data table. Initial Operate Time: 7 milliseconds, typical, with rated coil voltage applied. Initial Release Time: 2 milliseconds, typical, with zero volts applied (for unsuppressed relays after having been energized at rated coil voltage.)
Environmental Data Conditions
All parametric, environmental and life tests are performed according to EIA Standard RS-407-A at standard test conditions (23°C Ambient, 20-50% RH, 29.5 ± 1.0" Hg.) unless otherwise noted.