! Gain: +17 dB Typical ! Output Power: +18 dBm Typical ! Operating Temp. - 55 ºC to +85 ºC ! Environmental Screening Available Typical Intermodulation Performance at 25 º C Second Order Harmonic Intercept Point ....... +53 dBm (Typ.) Second Order Two Tone Intercept Point ........ +47 dBm (Typ.) Third Order Two Tone Intercept Point ............ +33 dBm (Typ.) Specifications CHARACTERISTIC Frequency TYPICAL Ta= 25 ºC 10 - 300 MHz MIN/MAX Ta = -55 ºC to +85 ºC 10 - 300 MHz Gain (dB) Power @ 1 dB Comp. (dBm) Reverse Isolation (dB) 17 +18 -26 16 Min. +17 Min. -25 Max. VSWR In Out 1.5:1 1.5:1 1.6:1 Max. 1.6:1 Max. Noise Figure (dB) 3.5 3.8 Max. Power Vdc +12 +12 m A 68 75 Max. Note: Care should always be taken to effectively ground the case of each unit.
MAXIMUM RATINGS
Ambient Operating Tempe
This website uses cookies or similar technologies, to enhance your browsing experience and provide personalized recommendations. By continuing to use our website, you agree to our Privacy Policy