Datasheet4U Logo Datasheet4U.com

2R470A-6S - GAS DISCHARGE TUBES

Download the 2R470A-6S datasheet PDF. This datasheet also covers the 2R400A-6S variant, as both devices belong to the same gas discharge tubes family and are provided as variant models within a single manufacturer datasheet.

Key Features

  • D Size:4.2mm.
  • 6.0mm D DC Spark-over voltage: 75~3000V D Stable breakdown voltage. D High insulation resistance. D Low capacitance (.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (2R400A-6S-SunMate.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number 2R470A-6S
Manufacturer SunMate
File Size 1.55 MB
Description GAS DISCHARGE TUBES
Datasheet download datasheet 2R470A-6S Datasheet

Full PDF Text Transcription for 2R470A-6S (Reference)

Note: Below is a high-fidelity text extraction (approx. 800 characters) for 2R470A-6S. For precise diagrams, and layout, please refer to the original PDF.

2R-6S SERIES GAS DISCHARGE TUBES Gas discharge tubes (GDT) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.The ceramic ...

View more extracted text
s to provide an alternate circuit path for voltage spikes.The ceramic envelope and with nickel connectors allow for high loads and Ruilon offers products that function at 20KA,40KA,50KA,60KA,100KA&150KA.The breakdown voltages of the devices have a wide range (up to 20% tolerance).Major applications are high frequency telecommunication lines,stations, security systems,HID and high quality Surge Protection Devices (SPD). Features D Size:4.2mm*6.0mm D DC Spark-over voltage: 75~3000V D Stable breakdown voltage. D High insulation resistance. D Low capacitance (<1pF) D High holdover voltage. D Large absorbing transient current c