DB155 - GLASS PASSIVATED BRIDGE RECTIFIER

Download the DB155 datasheet PDF. This datasheet also covers the DB151 variant, as both devices belong to the same glass passivated bridge rectifier family and are provided as variant models within a single manufacturer datasheet.

Key Features

  • ! Rating to1000VPRV ! Ideal forprintedcircuit board ! Low forwardvoltagedrop,highcurrent capability ! Reliablelowcost constructionutilizingmoldedplastic ! TheplasticmaterialhasUL flammability classification94V-0 Mechanical Data ! Polarit:AsmarkedonBody ! Weight:0.02ounces,0.38gras ! Mountingposition:Any DB - 1 .255(6.5) .245(6.2) .310(7.9) .290(7.4) .365(9.3) .355(9.0) .060(1.5) .020(.51) .016(.41) .205(5.2) .195(5.0) .135(3.4) .155(2.9) .165(4.2) .155(3.9) .350(8.9) .300(7.6) Maximum R.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (DB151-Sunmate.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number DB155
Manufacturer Sunmate
File Size 448.23 KB
Description GLASS PASSIVATED BRIDGE RECTIFIER
Datasheet download datasheet DB155 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
DB151-DB157 GLASS PASSIVATED BRIDGE RECTIFIER VOLTAGE RANGE: 50 - 1000V CURRENT: 1.5 A Features ! Rating to1000VPRV ! Ideal forprintedcircuit board ! Low forwardvoltagedrop,highcurrent capability ! Reliablelowcost constructionutilizingmoldedplastic ! TheplasticmaterialhasUL flammability classification94V-0 Mechanical Data ! Polarit:AsmarkedonBody ! Weight:0.02ounces,0.38gras ! Mountingposition:Any DB - 1 .255(6.5) .245(6.2) .310(7.9) .290(7.4) .365(9.3) .355(9.0) .060(1.5) .020(.51) .016(.41) .205(5.2) .195(5.0) .135(3.4) .155(2.9) .165(4.2) .155(3.9) .350(8.9) .300(7.6) Maximum Ratings and Electrical Characteristics TA = 25°C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.