FEATURES
►► Up to ±100V input voltage protection ►► Low on resistance - 15Ω typical ►► Integrated clamp diodes ►► Fast switching speed ►► Four electrically isolated channels ►► No external supplies needed APPLICATIONS
►► Medical ultrasound imaging ►► NDT applications ►► Fast resettable fuses ►► High side switches ►► Data acquisition GENERAL DESCRIPTION
The Supertex The analog switch terminals are Tx and Rx. Rx has integrated clamping diodes to RGND to protect the receiver against high voltages. Voltages greater than ±0.6V will start forward biasing the clamp diodes to RGND. The MD0101 can be considered as a normally closed switch with a typical switch resistance of 15Ω, allowing small signals to pass. Once the voltage drop across the switch exceeds a nominal value of ±1.0V, the device will start to turn off. In the off state, the MD0101 can withstand up to ±100V across its terminals. A small amount of current, 200µA, is allowed to flow through. The MD0101 is not limited to just ultrasound applications.