MAXIMUM RATINGS
* Symbol VCC Tstg Supply Voltage Storage Temperature Parameter Value 18 -60 to +85 Unit V °C RECOMMENDED OPERATING CONDITIONS Symbol VCC TA Supply Voltage Operating Temperature, All Package Types Parameter Min 4.5 -10 Max 16 +70 Unit V °C ELECTRICAL CHARACTERISTICS
(TA =+25°C) Symbol Parameter Test Conditions VCC=5.0 V, RL =∞ VCC=15 V, RL=∞ R=1.0 kΩ to 100 kΩ Initial Accuracy C = 0.1 µF VCC=5.0 V and VCC=15 V VCC=5.0 V VCC=15 V VCC=5.0 V VCC=15 V V02=0 V, VCC=15 V V02=15 V, VCC=15 V VCC=15 V V04=0 V, VCC=15 V V04=15 V, VCC=15 V V06=0 V, VCC=15 V V06=10 V, VCC=15 V 0.4 2.6 9 1.1 4.5 Guaranteed Limits Min ICC Supply Current Timing Error Max 6.0 15 4 mA % Unit Vth VT IT VR IR Ith Idis VREF VOL Threshold Voltage Trigger Voltage Trigger Current Reset Voltage Reset Current Threshold Current (Note 1) 4.0 11 2.2 5.6 -2 0.5 1.0 -0.4 0.5 -0.5 0.25 100 V V µA V mA µA µA nA V V Discharge Leakage Current (Pin VCC=15 V, V07=15 V 7) Control Voltage Level Output Voltage Low VCC=15 V VC...