Click to expand full text
R
TDK SMD Transformers
Photoflash Capacitor Charging Transformer
LDT565630T-002
Mechanical
RoHS Compliant: Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retar dants, PBB and PBDE, have not been used except for exempted applications. Top view Bottom view
5
002
4
5.8 MAX
6
3
7
2
8
1
( 0.85 ) 5.8 MAX 3.0 MAX
( 3.9 ) 5.6 +/- 0.2
( 0.85 )
Pad Layout
0.4 0.6
Note : Non applicable application : Military, Medical.
1
1
1
1
1
1
Electrical Specifications at 25degreesC
1. Inductance 5 - 8 : 14.5uH +/-15% at 100kHz, 20mVrms
1.3
3.6 6.2
1.3
Mass : 0.25 g
Unit : mm.
2. Leakage Inductance 5 - 8 ( short 1 - 4 ) : 500nH MAX at 100kHz, 20mVrms 3.