General Purpose Low Power PCB Relays
Power PCB Relay RT1 sensitive
n 1 pole 10A, 1 form C (CO) or 1 form A (NO) contact n Highly sensitive version, coil power 250mW n 5kV/10mm coil-contact n Reinforced insulation n Ambient temperature 85°C
SCHRACK
Typical applications Domestic appliances, heating control.
Z b
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400 VAC
Rated current
10A
Limiting making current; max. 4s, duty factor 10% 15A
Breaking capacity
2500VA
Contact material
AgNi 90/10
Frequency of operation; with/without load 3000/72000h-1
Operate/release time max.