TE Connectivity V23030-C1021-A104
Signal Relay
Signal Relays Card SN Relay V23030 n Low profile, therefore particularly suited for flat pack components grouping n For relays with 1 or 2 form C (CO) contacts: - creepage and clearance distances between contacts and frame >5mm or >10mm (depending on the relay version) - dielectric strength between contacts and frame 4kVrms or 6kVrms Typical applications measuring and control systems, alarm and security equipment, road traffic and railway signaling systems AXICOM Contact Data A104 A106 Contact arrangement 4 form C, 6 form C, (4 CO) (6 CO) Max. switching voltage 250VDC 250VDC 250VAC 250VAC Limiting continuous current ≤50°C ambient 2A 2A ≤75°C ambient 1A 1A Limiting making/breaking current 3A1) 3A1) Contact material Ag, Ag, Au-flashed Au-flashed Contact style bifurcated contacts Frequency of operation, without load max. 30 operations/s Operate / release time approx. 8/2ms Max. DC breaking capacity (contacts Ag) Curve 1: arc extinguished within contact transit period (limit curve I) Curve 2: safe breaking, erc extinguished (limit curve II) Contact Data (continued) Mechanical endurance aaprox.