DESCRIPTION
LD24KKW LD24KKY Solid State Relay with Short Circuit Protection and Trip Status Solid State Relay with Short Circuit Protection and Trip Status ELECTRICAL SPECIFICATIONS
(–55°C to +125°C UNLESS OTHERWISE NOTED) INPUT (CONTROL) SPECIFICATIONS When used in 2 terminal configuration (TTL or direct control) Min Typ Max Input Current @ VIN = 5 VDC 35 (See Fig 2) Turn-Off Voltage (Guaranteed Off) 1.5 Turn-On Voltage (Guaranteed On) 4.2 Reverse Voltage Protection -32 Input Supply Range (See Note 1, 7) 4.2 16 Units mA VDC VDC VDC VDC INPUT (CONTROL) SPECIFICATIONS When used in 3 terminal configuration (CMOS or open collector TTL) Min Typ Max Control Current VCONTROL = 5 VDC VCONTROL = 18 VDC (See Note 7) 500 2.0 Control Voltage Range (See Note 7) 0 18 Bias Supply Voltage (See Note 1, 7) 4.2 16 Bias Supply Current @ VBIAS = 5 VDC 35 Control Turn-Off Voltage 3.2 (Guaranteed Off) Control Turn-On Voltage 0.3 (Guaranteed On) Units μADC mADC VDC VDC mA VDC VDC OUTPUT (LOAD) SPECIFICATIONS (See Note 2) Min Typ Max Continuous Load Current (See Fig.