GENERAL DESCRIPTION
Available either in through-hole or surface-mount packages, the BTA/BTB04 - 600 triac series is suitable for general purpose AC switching. They can be used as an ON/OFF function in applications such as static relays, heating regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers, ... BTA/BTB04-600 ABSOLUTE MAXIMUM RATINGS
( Ta = 25 C) PARAMETER Repetitive peak off-state voltages peak off-state reverse voltages RMS on-state current Non-repetitive peak on-state current Max. Operating Junction Temperature Storage Temperature Symbol VDRM VRRM IT ITSM Tj Tstg Value 600 600 4.0 42 110 -45~150 Unit V V A A o O A1 A2 G C o TO-220AB C ELECTRICAL CHARACTERISTICS
( Ta = 25 C) PARAMETER Repetitive peak off-state voltages Repetitive peak off-state current On-state voltage Holding current T2+G+ Gate trigger Current T2+GT2-GT2-G+ T2+G+ Gate trigger Voltage T2+GT2-GT2-G+ Symbol Test Conditions ID=0.1mA VDRM=520V IT=5.5A IT=0.5A,IGT=20mA Min.