• Part: FS24-250-C2
  • Description: CLASS 2/3 TRANSFORMER
  • Manufacturer: TRIAD MAGNETICS
  • Size: 103.25 KB
Download FS24-250-C2 Datasheet PDF
TRIAD MAGNETICS
FS24-250-C2
FS24-250-C2 is CLASS 2/3 TRANSFORMER manufactured by TRIAD MAGNETICS.
Description : The FS24-250-C2 is a series/parallel primary and dual secondary, split bobbin design which operates with either a parallel input of 115V or a series input of 230V. The secondaries are 12V @ 0.25A each. They can be used independently (up to 300V difference between them) or in series for double the voltage or in parallel for double the current. The split bobbin design eliminates the need for costly electrostatic shielding. Electrical Specifications (@25C) 1. Maximum Power: 6.0VA 2. Primary: Series: 230V; Parallel: 115V 3. Secondaries: 12.0V @ 0.25A each 4. Voltage Regulation: 25% TYP @ full load to no load 5. Operating Temperature: -40C to 100C 6. Storage Temperature: -55C to 150C 7. Hipot tested 100% at 4200 VRMS pri to sec 8. Hipot tested 100% at 2160 VRMS sec to sec 9. Remended fuse (fuse on primary): For 115V - Cooper/Bussman, Type MDL, rated 500m A, 250V. For 230V - Littlefuse, Type 313, rated 250m A, 250V Construction: Three flange bobbin construction with primaries and secondaries wound side by E side for low capacitive coupling. UL Class F Insulation System (155°C). Agency File: UL: File E65390, UL 5085-1 & 3 (1585), Class 2 not wet / Class 3 wet Transformer c UL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06) TUV Certificate No.: R72120839, EN61558, Safety Isolating xfmr, general use Dimensions: 1.398 MAX 1.331 MAX Weight: 0.44 lbs 1.650 MAX 0.250±0.02 0.350±0.02 1.280±0.02 Units in inches. 0.041 0.020 0.217±0.02 Schematic: PARALLEL...