Datasheet4U.com

FS24-250-C2 Datasheet PDF

TRIAD MAGNETICS FS24-250-C2

The FS24-250-C2 is a series/parallel primary and dual secondary, split bobbin design which operates with either a parallel input of 115V or a series input of 230V. The secondaries are 12V @ 0.25A each. They can be used independently (up to 300V difference between them) or in series for double the voltage or in parallel for double the current.
Part No. FS24-250-C2
Datasheet FS24-250-C2 Download
Manufacturer TRIAD MAGNETICS
Description CLASS 2/3 TRANSFORMER
Buy Stock & Price
FS24-250-C2 datasheet page 1 preview

DESCRIPTION

: The secondaries are 12V @ 0.25A each. The split bobbin design eliminates the need for costly electrostatic shielding.

ELECTRICAL SPECIFICATIONS

(@25C) 1. Maximum Power: 6.0VA 2. Primary: Series: 230V; Parallel: 115V 3. Secondaries: 12.0V @ 0.25A each W 4. Voltage Regulation: 25% TYP @ full load to no load 5. Operating Temperature: -40C to 100C 6. Storage Temperature: -55C to 150C 7. Hipot tested 100% at 4200 VRMS pri to sec 8. Hipot tested 100% at 2160 VRMS sec to sec 9. Recommended fuse (fuse on primary): For 115V - Cooper/Bussman, Type MDL, rated 500mA, 250V. For 230V – Littlefuse, Type 313, rated 250mA, 250V Construction: Three flange bobbin construction with primaries and secondaries wound side by E side for low capacitive coupling. UL Class F Insulation System (155°C). Agency File: UL: File E65390, UL 5085-1 & 3 (1585), Class 2 not wet / Class 3 wet Transformer cUL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06) TUV Certificate No.: R7212083...