FEATURES
s s s s s s Linearized Temperature-to-Voltage Converters Direct Centigrade Output Voltage Scaling (TC03) Wide Temperature Measurement Range (TC02) ............................... – 20°C to +125°C Excellent Temperature Converter Linearity .. 0.8°C Over Temperature High Temperature Converter Accuracy .......... ±2°C at 25°C Guaranteed Small Packages ................ TO-92-3 and SOT-23B-3 GENERAL DESCRIPTION
The TC02/03 temperature sensors furnish a linearized output voltage directly proportional to measured temperature. VOUT = 10mV/°C x Temperature °C). An external pull-down resistor to a negative voltage source is required for temperature measurement below 0°C. It has the same output voltage slope with temperature as the TC03 (10mV/°C). The output voltage range is 300mV at – 20°C to 1,750mV at +125°C. Small size, low cost and low power operation make the TC02/03 suitable for a wide range of general purpose temperature measurement applications. APPLICATIONS
s s s s s Power Suppl...