RX2
RX2 is Power PCB Relay manufactured by Tyco Electronics.
General Purpose Relays
SCHRACK
Power PCB Relay RX2
I I I I I I
2-pole 8 A, 2 CO contacts DC- or AC-coil Reinforced insulation Height 15.7 mm Transparent cover optional Ro HS pliant (Directive 2002/95/EC) as per product date code 0413
..
Applications Domestic appliances, heating control, emergency lighting, automatic doors
S0271-A
Approvals
V REG.-Nr. A651, Z E214025 Technical data of approved types on request
Contact data
Contact configuration Contact set Type of interruption Rated current Rated voltage / max.switching voltage AC Maximum breaking capacity AC Limiting making capacity, max 4 s, duty factor 10% Contact material Mechanical endurance DC coil AC coil Rated frequency of operation with / without load Contact Type RX4 RX4 ratings Load 8 A, 250 VAC, 70°C, EN61810-1 8 A, 250 VAC, 70°C, UL508 General purpose 2 CO single contact micro disconnection 8A 240/400 VAC 2000 VA 15 A Ag Ni 90/10 > 5 x 106 cycles > 1 x 106 cycles 6 / 600 min-1
Cycles 4x104 4x104
Coil data
Rated coil voltage range DC coil AC coil Coil power DC coil AC coil Operative range Coil insulation system according UL1446 5...110 VDC 24...230 VAC 520 m W typ 0,75 VA 2 class F
Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm m W 005 5 3.5 0.5 50+10% 500 006 6 4.2 0.6 68+10% 529 012 12 8.4 1.2 274+10% 526 024 24 16.8 2.4 1095+10% 526 048 48 33.6 4.8 4380+10% 526 060 60 42.0 6.0 6845+10% 526 110 110 77.0 11.0 23010+10% 526 All figures are given for coil without preenergization, at ambient temperature +23°C
Datasheet Rev. GG1 Issued 2007/07 .tycoelectronics. .schrackrelays. Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays. in the ‘Schrack’ section....