Click to expand full text
Tyco / Electronics Raychem Circuit Protection 308 Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 FAX 800-227-4866
PolySwitch® PTC Devices
Overcurrent Protection Device
PRODUCT: TR600-150-RB
DOCUMENT: SCD 24064 PCN: 688511 REV LETTER: C REV DATE: MARCH 5, 2002 PAGE NO.: 1 OF 1
Specification Status: Released
Max Electrical Rating at 20°C
Operating Voltage: 60VDC Fault Voltage: 600VRMS Interrupt Current: 3ARMS Lead Material : 22 AWG Sn/Pb plated copper Marking:
Raychem Logo and Voltage Part Identification Lot Identification
600 150
TABLE I. DIMENSIONS:
A mm: in: MIN --MAX 13.5 (0.531) MIN --B MAX 12.6 (0.496) MIN --C MAX MIN 6.0 4.7 (0.236) (0.185) D MAX --E NOM 5.0 (0.197) F MIN --MAX 10.0 (0.394)
TABLE II.