RP310012
PCB Relay RP II/1
1 pole 8 / 12 / 16 A
- -
- -
1 C/O or 1 N/O contact 4 k V / 8 mm coil-contact Pinning 3.5 or 5 mm (8 / 12 A) and 5 mm (16 A) PCB-sockets
Applications Power supplies, domestic appliances, heating control, installation
F0146-B
VUC s 12 A version: V U C K s 16 A version: V U C s
8 A version:
Technical data of approved types on request
Contact data Configuration 1 C/O contact or 1 N/O contact Type of contact single contact Rated current 8A 12 A 16 A Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac Maximum breaking capacity AC 2000 VA 3000 VA 4000 VA Make current 16 A 20 A 25 A Contact material Ag Ni 0.15 Ag Cd O Ag Cd O
Contact Type RP410 RP410 RP418 RP411 RP412 RP330 RP330 life Load 12 A, 250 Vac, cosj=1, 1200/h, 40% duty cycle 9.1 A, 220 Vac, cosj=1, 360/h, 15% duty cycle 3.4 A ON, 0.42 A OFF, 220 Vac, cosj=0.6 8 A, 250 Vac, cosj=1, 50% duty cycle 8 A, 250 Vac, cosj=1, 50% duty cycle 18.2 A, 250 Vac, cosj=1, 600/h, 15% duty cycle 96 A ON, 16 A OFF, 250 Vac,...