Datasheet4U.com

U4082B Datasheet PDF

Unisonic Technologies U4082B

U4082B includes the necessary amplifiers, attenuators, level detectors and control algorithm. The dial tone can be pretended from being attenuated by the receive background noise monitor circuit by a dial tone detector.
Part No. U4082B
Datasheet U4082B Download
Manufacturer
Unisonic Technologies
Description VOICE SWITCHED SPEAKER-PHONE CIRCUIT
Buy Stock & Price
U4082B datasheet page 1 preview

DESCRIPTION

As a voice switched speaker-phone integrated circuit, the UTC To form the UTC U4082B’s internal circuit, there is an internal microphone amplifier with adjustable gain and mute control, internal transmit and Receive attenuators (operate in a complementary manner), level detectors at both input and output of both attenuators, and background noise monitors for both the transmit and receive channels. There are also two line driver amplifiers which can be used to form a hybrid network in conjunction with an external coupling transformer. A high-pass filter can be used for other filtering functions, and especially to filter out 60Hz noise in the receive channel. The UTC U4082B which requiring typically 5mA may be operated from a power supply, or it can be powered from the telephone line. „

FEATURES

* Attenuator gain range: 52dB (between Transmit and Receive) * For line-powered applications : 3~6.5V low voltage operation * For improved sensitivity :4-point signal sensing * For Tr...
U4082B page 2 preview U4082B page 3 preview