UM2312
UM2312 is 7.5 Watt DC-DC Converters manufactured by Universal Microelectronic.
- Part of the UM2300 comparator family.
- Part of the UM2300 comparator family.
UMEC International Corporation
UM2300 SERIES
7.5 Watt DC-DC Converters
- 2:1 Input Range
- Efficiency to 82%
- Pi Input Filter
- Short Circuit Protection
- 200KHz Switching Frequency
- Six-Sided Shield
- Conductive EMI Meets CISPR22 Class A
SPECIFICATIONS
All specifications are typical at nominal line, full load and 25°C unless otherwise noted.
OUTPUT SPECIFICATIONS
Voltage Accuracy: Single Output ……..……………………….……. ±1% max. Dual,+ Output …………….…………………….. ±1% max.
- Output …...…….…………..………….… ±1% max.
Voltage Balance, Dual Output at Full Load .….…………………………………….…………… ±1% max.
Transient Response Single,25% step load change ……..……….. <200 u sec. Dual, FL-1/2FL, ±1% Error Band …..………. <200 u sec.
Ripple and Noise, 20MHz-BW ………….…. 75m V P-P max. Temperature Coefficient ………….……..… ±0.02%/°C max. Short Circuit Protection ……………………….… Continuous Line Regulation1……………………………… ±0.2% max. Load Regulation2, Single Output ……..……….. ±0.5% max.
Dual Output ……………..….. ±1.0% max.
GENERAL SPECIFICATIONS
INPUT SPECIFICATIONS
Efficiency ………………..…………………..……... See Table Isolation Voltage …………………………….. 1500 VDC min. Isolation Resistance …..……………………… 108 ohms min. Switching Frequency ……………………………….. 200 KHz Operating Temperature Range,
Ambient, None Derating ………..…….... -25°C to +71°C Cooling ……………….……………... Free Air Convection Storage Temperature Range ……………... -55°C to +105°C EMI/RFI ……..………………… Six-Sided Continuous Shield Dimensions …………………………………… 2- 1- 0.4 inches
(50.8- 25.4- 10.2 mm) Case Material3 ………………….. Black-Coated Copper with
Non-Conductive Base Weight …………………………………………………...…. 30g
Input Voltage Range,12V ……………………………… 9-18V 24V ……………………………. 18-36V 48V ……………………………. 36-72V
Input Filter …………………………………………. Pi Network
UMEC UMEC International Corporation
2570 West 237th Street, Suite B
TIo Nrra Tnc Ee, RCa Nlifo Arn Tia I90O50N5 UASAL
NOTES
1. Measured from high line to low line. 2. Measured from full load to 1/4 full load (single).
Measured from full load to 1/2 full load (dual). 3....