VITROHM KH206
Power Wirewound Resistors
ELECTRICAL SPECIFICATIONS
Type Nominal Power rating P70 Resistance range E-Series Tolerances Temperature coefficient Temperature range Thermal resistance Dielectric withstanding voltage IEC115-1 clause 4.7 (1[min]) Insulation resistance IEC115-1 clause 4.6 Max. working voltage [W] Min [Ω] Max ± [%] [10-6*K-1] [ºC] [KW-1] 206-8 4 9K1 208-8 5 15K 210-8 212-8 214-8 216-8 779 *Please check the table below 11 33K 15K 33K 47K 218-8 17 82K E24 (5[%]), E12 (10[%]) 5, 10 *Depends on the value, please check the table below -55 … +350 70 56 40 40 31 25 16 [V] 2000 [MΩ] [V]RMS >104 PERFORMANCE DATA Derating linear Climatic category Failure Rate (Total, , max, 60% cont. lev.) Endurance IEC60115-1 clause 4.25 (P70, @ 70[°C], 1000[h]) Damp heat, steady state IEC115-1clause 4.24 (40[°C], 93[% r.h.], 56[d]) Climatic sequence IEC115-1 clause4.23 Terminal strength Terminal Tensile Strength Resistance to soldering heat IEC115-1 clause 4.18 (260±5[°C], 3,5±1[s]) Solderability IEC 60068-2-20 (245±5[ºC], 3±0.5[s]) Marking IEC60062 [ºC] [10-9 h-1] ± [%] ± [%] ± [%] ± [%] [N] ± [%] 70…350 (0W) 55/200/21 appr.