VTI technologies SCL1700
Inclinometer Subassembly
FEATURES
● Available range: ±10 °● DC…3 Hz sensing bandwidth (controlled frequency response)
● Easy to use and design in
● 0.001 ° resolution analogue output
● 0.2 ° accuracy
● Dual axis inclination measurement
● Advanced failure detection BENEFITS
● Excellent long term stability
● Sensing element filtered high frequency vibration
● Outstanding shock durability
APPLICATIONS
● Platform tilt measurement● Equipment and instrument condition monitoring
● Inclination based position measurement For customized product please contact VTI Technologies
ELECTRICAL CHARACTERISTICS
Parameter Supply voltage Output load Operating temperature Mechanical shock 1 m drop on concrete (1 Condition Min 7 Typ. 15 4.5 T.B.D T.B.D. Max 28 Units V mA kOhm nF Current consumption Resistive Capacitive -40 85 20 000 °C g PERFORMANCE CHARACTERISTICS Parameter Measuring range (1 Measuring axis Offset(2,3 Offset calibration error (3,4 Offset temperature error (3,5 Sensitivity (3,6 Sensitivity calibration error(3,7 Sen...