Datasheet4U Logo Datasheet4U.com

C1379 - Standard 4-Pin DIP Package

Key Features

  • Standard 4-Pin DIP Package (Half Size) Enable Function Previous Vectron Model Numbers Frequency range MCO1XXX; AB; 1 MHz.
  • 100 MHz Frequency stabilities1 Parameter Overall (vs. Initial, vs. operating temperature range vs. supply voltage change vs. load change vs. aging /1. Yea)r Min -100.0 -50.0 -25.0 -100.0 -50.0 -32.0 Typ Max. +100.0 +50.0 +25.0 +100.0 +50.0 +32.0 Units ppm ppm ppm ppm ppm ppm Operating temp range -0 … +70°C -0 … +70°C -0 … +70°C -40 … +85°C -40 … +85°C -40 … +85°C.

📥 Download Datasheet

Datasheet Details

Part number C1379
Manufacturer Vectron International
File Size 58.20 KB
Description Standard 4-Pin DIP Package
Datasheet download datasheet C1379 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
www.DataSheet4U.com C1379 PXO Typical Applications Telecommunication Universal Clock Features Standard 4-Pin DIP Package (Half Size) Enable Function Previous Vectron Model Numbers Frequency range MCO1XXX; AB; 1 MHz – 100 MHz Frequency stabilities1 Parameter Overall (vs. Initial, vs. operating temperature range vs. supply voltage change vs. load change vs. aging /1. Yea)r Min -100.0 -50.0 -25.0 -100.0 -50.0 -32.0 Typ Max. +100.0 +50.0 +25.0 +100.0 +50.0 +32.0 Units ppm ppm ppm ppm ppm ppm Operating temp range -0 … +70°C -0 … +70°C -0 … +70°C -40 … +85°C -40 … +85°C -40 … +85°C Ordering Code5 C104 C505 C255 F104 F505 F325 Supply voltage Parameter Supply voltage (Vs) Current consumption Min 4.75 Typ 5.0 Max. 5.25 40 50 55 70 3.