C2530
Typical Applications
PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop
TCXO
Features
Wide Frequency range EFC Standard Standard Surface Mount Package Meets Stratum 3 STO200
Previous Corning Model Numbers Frequency range Standard frequencies Frequency stabilities1 [ Standard TCXO]
www.DataSheet4U.com Parameter
30 MHz – 900 MHz 67.584; 69.12; 79.488; 155.52, 242.733, 278.08 MHz
Min -2.0 -1.0 -1.0 -0.5 Min - 1.0 - 0.2 - 0.2 - 1.0
Typ
Max. +2.0 +1.0 +1.0 +0.5 Max. +1.0 +0.2 +0.2 +1.0
Units ppm ppm ppm ppm Units ppm ppm ppm ppm
vs. operating temperature range (Referenced to +25°C)
Parameter Initial tolerance vs. supply voltage change vs. load change vs aging /1.