Vectron International
TFS110P
file: tfs110p.doc version 2.1 05.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 110P 1/4 ____________________________________________________________________________________________________ Measurement condition Ambient temperature: 23°C Input power level: 0 d Bm Terminating impedances for input: 2,9 kΩ || -6.2 p F for output: 2,8 kΩ || -5.5 p F Characteristics Remark: Reference level for the relative attenuation arel of the TFS 110 P is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 d B filter attenuation level relative to the insertion loss ae. Data ____________________________________________________________________________________________________ ae = amin Insertion loss 8 d B 10 d B (reference level)...