Overview: .vishay. IHLP-2020AB-01
Vishay Dale IHLP® mercial Inductors, High Saturation Series DESIGN SUPPORT TOOLS click logo to get started Models
Available Design Tools Available STANDARD ELECTRICAL SPECIFICATIONS L0 INDUCTANCE HEAT ± 20 % DCR DCR RATING SATURATION AT 100 kHz, TYP. MAX. CURRENT CURRENT SRF 0.25 V, 0 A 25 °C 25 °C DC TYP. DC TYP. TYP. (μH) (mΩ) (mΩ) (A) (1) (A) (2) (MHz) 0.10 4.32 4.60 13.5 35 256 0.47 18.2 19.2 6.5 18 108 1.0 44.3 46.5 4.4 10.2 64 2.2 73.6 77.3 3.4 6 47 3.3 98.4 103 2.8 5 33 4.7 159 168 2.2 4.4 30 Notes
• All test data is referenced to 25 °C ambient
• Operating temperature range -55 °C to +125 °C
• The part temperature (ambient + temp. rise) should not exceed 125 °C under worst case operating conditions. Circuit design, ponent placement, PWB trace size and thickness, airflow and other cooling provisions all affect the part temperature.