MOC8021
Features
- High collector-emitter breakdown voltage, 80 V minimum
- High isolation resistance, 1011 Ω typical
- Standard plastic DIP Package
- No base terminal connection for improved mon mode interface immunity
- Lead-free ponent
- ponent in accordance to Ro HS 2002/95/EC and WEEE 2002/96/EC
A C NC
1 2 3
6 NC 5 C 4 E i179013 e3
Pb
Pb-free
Agency Approvals
- UL1577, File No. E52744 System Code H or J, Double Protection
- DIN EN 60747-5-2 (VDE0884) DIN EN 60747-5-5 pending Available with Option 1 used to replace reed and mercury relays with advantages of long life, high speed switching and elimination of magnetic fields.
Order Information
Part IL55B IL56B MOC8021 IL55B-X006 IL55B-X009 IL55B-X007 Remarks CTR > 500 %, DIP-6 CTR > 1000 %, DIP-6 CTR > 1000 %, DIP-6 CTR > 500 %, SMD-6 (option 7) CTR > 500 %, SMD-6 (option 9) CTR > 500 %, SMD-6 (option 7)
Description
The IL5x B and MOC8021 are optically coupled isolators with a gallium arsenide infrared LED and a silicon...