Overview
PTS0805M PTS1206M Resistance values R0 at 0 °C 100 , 500 100 , 500 , 1000 Temperature coefficient (0 °C to +100 °C) +3850 ppm/K Tolerance classes F0.3, F0.6 Temperature range -55 °C to +175 °C Long term stability |R0/R0|; R0 change after 1000 h at +155 °C Insulation resistance 0.1 % > 10 M 100 0.1 mA to 1.0 mA 0.1 mA to 1.0 mA Measurement current Imeas. (DC) (1) 500 1000 0.1 mA to 0.40 mA - 0.1 mA to 0.40 mA 0.1 mA to 0.25 mA Self-heating at 0 °C (2) Calm air (v = 0.0 m/s) 0.8 K/mW 0.7 K/mW Thermal response time (2) Flowing water (v = 0.4 m/s) Flowing air (v = 3.0 m/s) t0.5 0.2 s t0.9 0.3 s t0.5 1.5 s t0.9 3.0 s Notes (1) Indicated measurement currents can be applied continuously with self-heating effect of less then 0.1 °C. (2) Valid for sensor element only. t0.5 0.3 s t0.9 0.4 s t0.5 2.0 s t0.9 5.0 s 1 Document Num.
- Standardized characteristics according to