Hollow shaft Encoder WDG 58 H Electrical data: Design according to:: Power supply: Current consumption: Channels: Output: Load: Signal level: Pulse frequency: Circuit pro...
View more extracted text
on: Channels: Output: Load: Signal level: Pulse frequency: Circuit protection: Early-warning output: (Only G24, I24, G05, I05) Cable length: H24 / R24 H05 / R05 G24 / I24 245 G05 / I05 DIN VDE0160 DIN VDE0160 DIN VDE0160 10 - 30 VDC 10 - 30 VDC 4,75 - 5,5 VDC max. 70 mA max. 70 mA max. 70 mA see pulse diagram push-pull push-pull push-pull max. 40 mA max. 40 mA max. 40 mA at 20 mA at 20 mA at 20 mA H > UB- 2,5 VDC H > 2,5 VDC H > 2,5 VDC L < 2,5 VDC L < 1,2 VDC L < 0,5 VDC max. 200 kHz max. 200 kHz max. 200 kHz yes no no conducting when operating max. 100 m max. 100 m max. 100 m Output circuit G24/H24 (HTL): 10-30 V Output