WCM2801
AC / DC Sensing Current Module with Digital Data output
Feature:
Continuous output and Modbus-RTU version Operating voltage DC5.0V 98 mΩ internal conductor resistance Sensing current range :
AC : 0~0.5A (50Hz, 60Hz) DC : 0~±0.7A High accuracy : AC : (0~0.2A) ± 2mA
(0.2~0.5A) ± 1% DC : ±(0~0.2A) ± 2mA
±(0.2~0.7A) ± 1% High resolution : AC / DC : 0.6mA UART, Baud Rate : 9600 bps, Parity bit : None,Data bit : 8,Stop bit : 1 Temperature calibration Isolation Voltage 1KV Application note: http://www.winson.com.tw/Product/83
General Description:
The Winson WCM2801 provides economical and precise solution for both AC and DC current sensing in industrial, commercial and communications systems.