Integrated 12-bit Data Acquisition System for
Imaging Applications
Description
Features
WM8144-12 integrates the analogue signal conditioning required by CCD sensors with a 12-bit ADC and optional pixel-by-pixel image pensation. WM8144-12 requires minimal external circuitry and provides a cost effective sensor-to-digital domain system solution.
Each analogue conditioning channel provides reset level clamp, CDS, fine offset level shifting and gain amplification. The three channels are multiplexed into the ADC. Output from the ADC can either be direct or passed through a digital post-processing function. The postprocessing provides...