Datasheet Summary
A Dimensions: [mm]
B Remended land pattern: [mm]
D Electrical Properties:
Properties Inductance Rated current Saturation current DC Resistance DC Resistance Self resonant frequency Test conditions 100 kHz/ 5 mA ∆T = 40 K |ΔL/L| < 10% @ 20°C @ 20°C L IR Isat RDC RDC fres Value 27 4.3 3.1 42.5 37.6 15 Unit µH A A mΩ mΩ MHz Tol. ±20% max. typ. max. typ. typ.
C Schematic:
E General information:
It is remended that the temperature of the part does not exceed 150°C under worst case operating conditions.
- Ambient temperature: -40°C to +110°C (refering to IR)
- Operating temperature: -40°C to +150°C
- Storage temperature (on tape & reel): -20°C to +40°C; 75% RH max.
- Test conditions of...