APPLICATIONS

Convection-cooled Open Frame & U-Channel Versions Optional Power Fail Detect Signal Optional Low Temperature Operation Up to 90% Efficiency Specification Input Input Voltage Input Frequency Input Current
● 90-264 VAC (120-370 VDC)
● 47-63 Hz
● 2.0 A at 115 VAC 1.0 A at 230 VAC Inrush Current
● 20 A at 115 VAC 63 A at 230 VAC Power Factor
● >0.95 Earth Leakage Current
● <0.40 mA at 115 VAC <0.75 mA at 230 VAC Input Protection
● 3.15 A on board fuse General Efficiency Isolation
● 88% typical, 90% max
● 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground
● PWM 60 kHz typical, PFC 100 kHz typical
● 6.9 W/In3 for open frame version
● Power Fail Detect = TTL low (option)
● >100 kHrs per MIL-HDBK-217F Switching Frequency Power Density Signals MTBF Environmental Operating Temperature
● 0 °C to +70 °C, derate linearly from 100% load at +50 °C to 50% load at +70 °C, low temperature option ‘-L’ -40 °C Cooling
● Convection-cooled Operating Humidity
● 5-95% RH, n...