XP Power JCA0312S12
DC-DC Converters
DC-DC 2/3 Watts JCA Series xppower.com
● Compact 1.0” x 0.8” Metal Package
● Industry Standard Pin Out
● 2:1 Input Range
● Single & Dual Outputs
● Operating Temperature -40 °C to +100 °C
● UL & TUV Approved
● 3 Year Warranty Specification Input Input Voltage Range Input Current Input Filter Input Reflected Ripple Current Input Surge
● 5 V (4.5-9.0 VDC) 12 V (9-18 VDC) 24 V (18-36 VDC) 48 V (36-75 VDC) Turn On at >90-95% of rated input Turn Off at <80% of rated input
● See table
● Pi network
● 80 mA, 5 V input models, 30 mA all others 12 µH inductor, 5 Hz to 20 MHz
● 5 V models 10 V for 1 s max, 12 V models 25 V for 1 s max, 24 V models 50 V for 1 s max, 48 V models 100 V for 1 s max Output Output Voltage
● See table Initial Set Accuracy
● ±1% max Start Up Delay
● 30 ms max Start Up Rise Time
● 3.5 ms typical Minimum Load
● No minimum load required Line Regulation
● ±0.3% Load Regulation
● ±1% Cross Regulation
● ±5% on dual output models Transient Response
● 4% max deviation, recovery t...
● Compact 1.0” x 0.8” Metal Package
● Industry Standard Pin Out
● 2:1 Input Range
● Single & Dual Outputs
● Operating Temperature -40 °C to +100 °C
● UL & TUV Approved
● 3 Year Warranty Specification Input Input Voltage Range Input Current Input Filter Input Reflected Ripple Current Input Surge
● 5 V (4.5-9.0 VDC) 12 V (9-18 VDC) 24 V (18-36 VDC) 48 V (36-75 VDC) Turn On at >90-95% of rated input Turn Off at <80% of rated input
● See table
● Pi network
● 80 mA, 5 V input models, 30 mA all others 12 µH inductor, 5 Hz to 20 MHz
● 5 V models 10 V for 1 s max, 12 V models 25 V for 1 s max, 24 V models 50 V for 1 s max, 48 V models 100 V for 1 s max Output Output Voltage
● See table Initial Set Accuracy
● ±1% max Start Up Delay
● 30 ms max Start Up Rise Time
● 3.5 ms typical Minimum Load
● No minimum load required Line Regulation
● ±0.3% Load Regulation
● ±1% Cross Regulation
● ±5% on dual output models Transient Response
● 4% max deviation, recovery t...