XP Power JCK3024S3V3
DC-DC Converter
DC DC 30 Watts JCK Series xppower.com
● 2:1 Input Range
● Operating Temperature 40 °C to +75 °C
● Single and Dual Outputs
● High Efficiency Up to 92%
● Remote On/Off
● 1600 VDC Isolation
● 3 Year Warranty Specification Input Input Voltage Range Input Current Undervoltage Lockout Input Reflected Ripple Current Input Surge Input Filter
● 12 V (9-18 VDC), 24 V (18-36 VDC), 48 V (36-75 VDC)
● See table
● 12 V models: ON 8.6 V, OFF 7.9 V typical 24 V models: ON 17.8 V, OFF 16 V typical 48 V models: ON 33.5 V, OFF 30.5 V typical
● 20 mA pk-pk through 12 uH inductor
● 12 V models 25 VDC for 100 ms 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms
● Pi network Output Output Voltage
● See table Output Voltage Trim
● ±10% on single outputs models only Start Up Delay
● 30 ms max Minimum Load
● No minimum load required Line Regulation
● ±0.5% max Load Regulation
● Single output models: ±0.5% max Dual output models: ±1% max balanced outputs Cross Regulation
● ±5% (see note 2) Setpoint Ac...
● 2:1 Input Range
● Operating Temperature 40 °C to +75 °C
● Single and Dual Outputs
● High Efficiency Up to 92%
● Remote On/Off
● 1600 VDC Isolation
● 3 Year Warranty Specification Input Input Voltage Range Input Current Undervoltage Lockout Input Reflected Ripple Current Input Surge Input Filter
● 12 V (9-18 VDC), 24 V (18-36 VDC), 48 V (36-75 VDC)
● See table
● 12 V models: ON 8.6 V, OFF 7.9 V typical 24 V models: ON 17.8 V, OFF 16 V typical 48 V models: ON 33.5 V, OFF 30.5 V typical
● 20 mA pk-pk through 12 uH inductor
● 12 V models 25 VDC for 100 ms 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms
● Pi network Output Output Voltage
● See table Output Voltage Trim
● ±10% on single outputs models only Start Up Delay
● 30 ms max Minimum Load
● No minimum load required Line Regulation
● ±0.5% max Load Regulation
● Single output models: ±0.5% max Dual output models: ±1% max balanced outputs Cross Regulation
● ±5% (see note 2) Setpoint Ac...