XP Power JHM1024D15
DC to DC Converter and Switching Regulator
DC DC 10 Watts JHM10 Series
●
●
●
●
●
●
● xppower.com International Medical Approvals 4000 VAC Reinforced Insulation Meets IEC60601 1, 3rd Edition 2 µA Patient Leakage Current DIP 24 Package EN55011 Level A With No External Components 3 Year Warranty Specification Input Input Voltage Range
● 5 V (4.5-9 VDC) 12 V (9-18 VDC) 24 V (18-36 VDC)
● See table
● 20 A max at 36 V
● Pi network
● 2 µA max
● 5 V models, on at >4.4 V, off <4.2 V 12 V models, on at >8.8 V, off <8.3 V 24 V models, on at >17.5 V, off <17.0 V
● 5 V models 15 V for 3 s 12 V models 25 V for 3 s 24 V models 50 V for 3 s General Efficiency Isolation
● See tables
● 4000 VAC for 1 min. double/reinforced with a working voltage of 250 VAC. Meets 2 x MOPP per 3rd edition of IEC60601-1 5000 VAC for 10 ms in accordance with IEC60664-1
● 20 pF max
● 80 kHz to 1.2 MHz variable
● 20.0 W/in3
● >1 MHrs typical to MIL-STD-217F at 25 °C, GB Input Current Inrush Current Input Filter Patient Leakage Current Undervoltage Lockout Input to Ou...
●
●
●
●
●
●
● xppower.com International Medical Approvals 4000 VAC Reinforced Insulation Meets IEC60601 1, 3rd Edition 2 µA Patient Leakage Current DIP 24 Package EN55011 Level A With No External Components 3 Year Warranty Specification Input Input Voltage Range
● 5 V (4.5-9 VDC) 12 V (9-18 VDC) 24 V (18-36 VDC)
● See table
● 20 A max at 36 V
● Pi network
● 2 µA max
● 5 V models, on at >4.4 V, off <4.2 V 12 V models, on at >8.8 V, off <8.3 V 24 V models, on at >17.5 V, off <17.0 V
● 5 V models 15 V for 3 s 12 V models 25 V for 3 s 24 V models 50 V for 3 s General Efficiency Isolation
● See tables
● 4000 VAC for 1 min. double/reinforced with a working voltage of 250 VAC. Meets 2 x MOPP per 3rd edition of IEC60601-1 5000 VAC for 10 ms in accordance with IEC60664-1
● 20 pF max
● 80 kHz to 1.2 MHz variable
● 20.0 W/in3
● >1 MHrs typical to MIL-STD-217F at 25 °C, GB Input Current Inrush Current Input Filter Patient Leakage Current Undervoltage Lockout Input to Ou...