XP Power JTE0624D03
DC-DC Converter
DC-DC 6 Watts JTE Series xppower.com
● 4:1 Input Range
● DIP-24 Plastic Case
● Operating Temperature -40 °C to +100 °C
● Single & Dual Outputs
● Optional Metal Case
● 1500 VDC Isolation, 3000 VDC Option
● 3 Year Warranty Specification Input Input Voltage Range
● 24 V (9-36 VDC) 48 V (18-75 VDC) Input Current
● See table Input Filter
● Pi network Input Reflected Ripple
● 20 mA pk-pk through 12 µH inductor and 4.7 µF capacitor Input Surge
● 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms Under Voltage Lockout
● 24 V models on >8.5 V, off <8.0 V 48 V models on >16.5 V, off <15.5 V Output Output Voltage
● See table Output Voltage Balance
● ±2% max, dual output models Initial Set Accuracy
● ±2% max Minimum Load
● No minimum load required Line Regulation
● ±0.5% max Load Regulation
● ±1.2% max for single output and ±5% max for dual output from 10-100% Cross Regulation
● ±5% max on dual output models (see note 4) Start Up Delay
● 20 ms typical Ripple & Noise
● 80 mV pk-pk (100 mV for D24 models), 20 MHz bandwidth (see note 5) Transient Response
● <3% max deviation, recovery to within 1% in 300 µs for a 25% load change (4% max.
● 4:1 Input Range
● DIP-24 Plastic Case
● Operating Temperature -40 °C to +100 °C
● Single & Dual Outputs
● Optional Metal Case
● 1500 VDC Isolation, 3000 VDC Option
● 3 Year Warranty Specification Input Input Voltage Range
● 24 V (9-36 VDC) 48 V (18-75 VDC) Input Current
● See table Input Filter
● Pi network Input Reflected Ripple
● 20 mA pk-pk through 12 µH inductor and 4.7 µF capacitor Input Surge
● 24 V models 50 VDC for 100 ms 48 V models 100 VDC for 100 ms Under Voltage Lockout
● 24 V models on >8.5 V, off <8.0 V 48 V models on >16.5 V, off <15.5 V Output Output Voltage
● See table Output Voltage Balance
● ±2% max, dual output models Initial Set Accuracy
● ±2% max Minimum Load
● No minimum load required Line Regulation
● ±0.5% max Load Regulation
● ±1.2% max for single output and ±5% max for dual output from 10-100% Cross Regulation
● ±5% max on dual output models (see note 4) Start Up Delay
● 20 ms typical Ripple & Noise
● 80 mV pk-pk (100 mV for D24 models), 20 MHz bandwidth (see note 5) Transient Response
● <3% max deviation, recovery to within 1% in 300 µs for a 25% load change (4% max.