FEATURES
DIN CECC MIL Resistance Tolerance T.C.R. 44061, 45921 part 107 40101-039, 40101-017 10509F (Char. D & C ) ± 1% ± 50ppm/ºC DERATING CURVE INTRODUCTION 20 40 60 80 100 120 140 160 180 Rated Load (%) 100 80 60 40 20 70ºC Ambient Temperature (ºC) HOT -SPOT TEMPERATURE Surface Temp. Rise (ºC) 200 150 100 50 MF0207 MF0204 0 25 50 75 100 Measuring Position Applied Load, % of RCWV DIMENSIONS Unit : mm ød H L øD STYLE MF0204 MF0207 L 3.3± 0.4 6.3± 0.5 øD 1.8± 0.3 2.3± 0.3 H 28± 2.0 28± 2.0 ød 0.5± 0.05 0.6± 0.05 6 Note : ELECTRICAL CHARACTERISTICS
STYLE Power Rating at 70ºC Operating Temp. Range Maximum Working Voltage Maximum Overload Voltage Dielectric Withstanding Voltage Value Range ± 1% Temperature Coefficient MF0204 0.4W -55ºC to +155ºC 200V 400V 400V 10Ω~1MΩ ± 50ppm/ºC 300V 600V 500V MF0207 0.6W * Standard resistance is 10Ω~1MΩ, below or over this resistance on request. ENVIRONMENTAL CHARACTERISTICS PERFORMANCE TEST Short Time Overload Dielectric Withstanding Voltage Temperature...