Datasheet4U Logo Datasheet4U.com

INA193 - Current Shunt Monitor

General Description

The INA193 INA198 family of current shunt monitors with voltage output can sense drops across shunts at common-mode voltages from

16 V to +80 V, independent of the INA19x supply voltage.

They are available with three output voltage scales: 20 V/V, 50 V/V, and 100 V/V.

Key Features

  • 1 Wide Common-Mode Voltage:.
  • 16 V to +80 V.
  • Low Error: 3.0% Over Temp (maximum).
  • Bandwidth: Up to 500 kHz.
  • Three Transfer Functions Available: 20 V/V, 50 V/V, and 100 V/V.
  • Quiescent Current: 900 μA (maximum).
  • Complete Current Sense Solution 2.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Product Folder Sample & Buy Technical Documents Tools & Software Support & Community Reference Design INA193, INA194, INA195 INA196, INA197, INA198 SBOS307G – MAY 2004 – REVISED JANUARY 2015 INA19x Current Shunt Monitor −16 V to +80 V Common-Mode Range 1 Features •1 Wide Common-Mode Voltage: −16 V to +80 V • Low Error: 3.