Datasheet4U Logo Datasheet4U.com

INA200 - High-Side Measurement Current-Shunt Monitor

General Description

The INA200, INA201, and INA202 devices are highside current-shunt monitors with voltage output and integrated comparator.

16 V to 80 V.

Key Features

  • 1 Complete Current Sense Solution.
  • Three Gain Options Available:.
  • INA200 = 20 V/V.
  • INA201 = 50 V/V.
  • INA202 = 100 V/V.
  • 0.6-V Internal Voltage Reference.
  • Internal Open-Drain Comparator.
  • Latching Capability on Comparator.
  • Common-Mode Range:.
  • 16 V to 80 V.
  • High Accuracy: 3.5% Maximum Error Over Temperature.
  • Bandwidth: 500 kHz (INA200).
  • Quiescent Current: 1800 μA (Maximum).
  • Pac.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Product Folder Order Now Technical Documents Tools & Software Support & Community Reference Design INA200, INA201, INA202 SBOS374E – NOVEMBER 2006 – REVISED SEPTEMBER 2017 INA20x High-Side Measurement Current-Shunt Monitor With Open-Drain Comparator and Reference 1 Features •1 Complete Current Sense Solution • Three Gain Options Available: – INA200 = 20 V/V – INA201 = 50 V/V – INA202 = 100 V/V • 0.6-V Internal Voltage Reference • Internal Open-Drain Comparator • Latching Capability on Comparator • Common-Mode Range: –16 V to 80 V • High Accuracy: 3.