LM25056A Description

The LM25056A bines high performance analog and digital technology with a PMBus™ pliant SMBus™/I2C interface to accurately measure the operating conditions of electrical systems including puting and storage blades connected to a backplane power bus. The LM25056A continuously supplies real-time power, voltage, current, and temperature data to the system management host via the SMBus interface. The LM25056A monitoring...

LM25056A Key Features

  • 234 Input Voltage Range: 3V to 17V
  • I2C/SMBus Interface with PMBus pliant
  • Remote Temperature Sensing with Programmable Warning and Shutdown Thresholds
  • Real Time Monitoring of VIN, IIN, PIN, VAUX with 12-bit Resolution and 1 kHz Sampling Rate
  • Current Measurement Error: ±0.5%: +10°C to +85°C
  • Voltage Measurement Error: ±1.0%: +10°C to+85°C
  • Power Measurement Error: ±1.5%: +10°C to +85°C
  • True Input Power Measurement Using Simultaneous Sampling of VIN and IIN Accurately Averages Dynamic Power Readings
  • Averaging of VIN, IIN, PIN, and VAUX Over Programmable Interval Ranging from 0.001 to 4 Seconds
  • User Programmable WARN and FAULT Thresholds with SMBA Notification