LM25056A
Overview
The LM25056A combines high performance analog and digital technology with a PMBus™ compliant SMBus™/I2C interface to accurately measure the operating conditions of electrical systems including computing and storage blades connected to a backplane power bus. The LM25056A continuously supplies real-time power, voltage, current, and temperature data to the system management host via the SMBus interface.
- 234 Input Voltage Range: 3V to 17V
- I2C/SMBus Interface with PMBus Compliant Command Structure
- Remote Temperature Sensing with Programmable Warning and Shutdown Thresholds
- Real Time Monitoring of VIN, IIN, PIN, VAUX with 12-bit Resolution and 1 kHz Sampling Rate
- Current Measurement Error: ±0.5%: +10°C to +85°C
- Voltage Measurement Error: ±1.0%: +10°C to+85°C
- Power Measurement Error: ±1.5%: +10°C to +85°C
- True Input Power Measurement Using Simultaneous Sampling of VIN and IIN Accurately Averages Dynamic Power Readings
- Averaging of VIN, IIN, PIN, and VAUX Over Programmable Interval Ranging from 0.001 to 4 Seconds
- User Programmable WARN and FAULT Thresholds with SMBA Notification